Rola-chem RC554XXP Dual ORP/pH Digital Controller Manuel d'utilisateur Page 6

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 20
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 5
Rola-Chem Digital Controller PN 554326 02/17/2014 Page: 6 of 20
NOTE: When automating any body of water, it is essential to size the feeders to reach
desired levels in a relatively short period of time. Generally, automating an existing body of
water with existing feeders will require the output of the feeders be increased accordingly. If
feeders are unable to keep up with demand in a short period of time, automation becomes
ineffective.
3.2 Specifications
Parameter Display Control Factory Default .
pH: 6.8 to 8.4 7.0 to 8.0 7.4
ORP: 0 to 995 mV
ORP1: (5 mv increments) 400 mV to 900 mV 650mV
ORP1: (5 mv increments) 400 mV to 890 mV 640mV
Input Power
120 Volts AC, 50/60 HZ, 3 wire grounded power cord.
Combined load not to exceed 10 amps.
GFCI source required
Output Power
120 Volts AC, 50/60 HZ, ORP1, OPR2 and pH , 3.15 amps each (fused)
Two 3-wire grounded power receptacles
Terminal strip for hardwire applications (included)
Displays:
ORP and pH – red digital
Power and flow indicator – LED
Alert indicator & Feed indicator- LED (pH, ORP1& OPR2)
Mode indicator- LED (pH ,ORP1, ORP2 , Auto)
NOTE- feed lamps flash during the feed time and are on constant during the delay time of
the feed cycle.
Operating Temperature: 40 to 120° F
Selectable Features
+ ORP1& ORP2 settings +pH settings + Manual feed (Feed Once)
+ ORP1& ORP2 feed/delay times + pH feed/delay times + pH calibration
+High & low ORP and pH alerts + Reset
+ Acid/base feed + Keypad Lockout + Adjustable time-out
+ ORP and pH Interlock
Features and Options
+ Flow switch input + Individually fused outputs + 120 vac transformer